beautypg.com

Wavetronix Command Collector (CMD-DCx) - User Guide User Manual

Page 36

background image

CHAPTER 4 • SENSOR TOOLBAR

35

2 Enter the IP/Hostname of the sensor or communication server and the Port number

through which Collector will communicate. Ranges can be used to add more than one

sensor at the same time (see Figure 4.3).

Figure 4.3 – Add Sensor Info Fields

Depending on the sensor and communication setup, a multi-drop ID or a unit address

may be required. The Multi-drop ID field will not be displayed if it is not necessary for

the selected driver. In other cases, the Multi-drop ID field will be visible and relabeled

with a new name to correspond to the particular address or field name used by the

device for user clarity.

The Custom ID field is optional and can be used to enter any additional identification

information.

3 Enter the initial collection interval (in seconds) into the Collection Interval field. For

sensor drivers that support automatic querying of the sensor interval, the Use Sensor

Interval option will be displayed. Check this box to use the sensor interval as the col-

lection interval.

4 Select the time zone that the sensor resides in from the Time Zone drop-down list and

mark whether the sensor location observes daylight savings time. This will allow Col-

lector to adjust sensor time to local time for proper timekeeping and data storage (see

Figure 4.4).

Figure 4.4 – Additional Add Sensor Fields

The Start Collecting Data Immediately option determines whether data collection is

started or stopped for the new sensor once it is added. If the communication pathway

to the sensor is open, data collection can begin immediately; if the Start Collecting

Data Immediately option is checked, Collector will attempt to retrieve the sensor’s

configuration after it is added to the system. However, if the sensor is not connected

and configured properly, it is recommended that this option be turned off. If the op-

tion is not turned off, Collector will continue to attempt to connect and will simply log

errors after every collection interval.

The Attach to Multi-drop Server (if available) option is used when multiple sensors

share a common IP address and port. This option will only be available if the selected