Wavetronix Command Collector (CMD-DCx) - User Guide User Manual
Page 116
CHAPTER 9 • DRIVER REFERENCE
115
munication only).
˽
Timeout – Time in milliseconds Collector will attempt to make a modem connection
before returning.
˽
Retry Count – If Collector cannot make a modem connection in the timeout period
(or if it runs into a NO CARRIER error), it will try again this number of times before
abandoning the collection attempt completely.
˽
Read Delay (ms) – Milliseconds Collector will wait after sending a command before it
attempts to read the response.
˽
Device Password – Some Diamond devices are password protected and need a pass-
word sent for each command before it will respond.
˽
Daytime Collection – If not checked, the Diamond driver will ignore data collection
command during daytime hours (7 a.m. to midnight).