Endpoint service details, Dlci details screen – Verilink WANsuite 7205 (34-00317.B) Product Manual User Manual
Page 70

3-40
W A N s u i t e 7 2 0 5
The Endpoint Details screen provides the following user-activated buttons:
Endpoint Service Details
Clicking the Service Details button at the bottom of the Endpoint Table screen
displays the typical Service Details screen. Refer to the Service Details Screen
on page 3-17 for a complete description of this type of screen.
DLCI Details Screen
The Endpoint DLCI Details screen (Figure 3.32) lets you access the
configuration parameters described in the following paragraphs. To bring up
this screen, click the “Endpoint DLCI Details” button on the Endpoint Table
screen or the “DLCI Details” button on the Endpoint Details screen.
Figure 3.32
DLCI Details Screen
The unit uses the first three configuration parameters (Protocol Encapsulation,
Proprietary Traffic Type, and Proprietary Offset) to gather statistics. For in-
band management, “RFC 1490” must be the encapsulation method.
Button
Function
Submit
Sets any values that have been changed.
Service Details
Opens the Service details screen showing the selected service's
settings.
DLCI Details
Displays details of the selected DLCI.
Delete Endpoint
Deletes the currently displayed endpoint.
Refresh
Refreshes data on the current page.