3-6
W A N s u i t e 7 2 0 5
“Function” parameter (on the Network 2 screen) in Network mode
−
Internal,
Network 1, Network 3, Serial 1
Network 2
“Function” parameter in “Slaved” mode
−
timing parameter is ignored in
Slave mode
“Function” parameter in “Network” mode
−
Internal, Network 2, Serial 2
Definitions of the timing sources are as follows:
Internal – The unit’s internal frequency standard (E1 2.048 Mbps ± 50 bps)
is used for all timing.
Network 1, Network 2, Network 3 – Timing is derived from the Network
port recovered clock.
Serial 1, Serial 2 – Timing is derived from the Serial port recovered clock.
CRC4 Mode
Provides line integrity detection to determine if bit errors are present on the
line.
Values: Disable, Enable
Default: Disable
Error Status and Alarm Thresholds Table
The unit can be programmed to generate an alarm condition based on a
specific level of performance degradation. The Network screens present a
table that provides current error status and alarm threshold information.
Acceptable alarm thresholds are set for periods of 15 minutes (900 seconds)
and sampled every second. The error types listed in the paragraphs below can
be preset to a value between 0 and 900 seconds. Setting a field to “0” (zero)
disables the alarm on that statistic. To effectively disable alarm reporting, set
all fields to “0” (zero).
The 15-minute time frame is not based on the TR 54016 or T1.403 interval
boundaries, but is a time window based on the accumulated counts over the
previous fifteen 1-minute intervals. In all cases, if the number of actual
network errored seconds in the previous 15 minutes reaches the preset
threshold for the specified error type, an alarm condition is declared.
The four columns of the status table are as follows:
The table provides error status and alarm threshold information for the
following error parameters:
•
Status
Displays the current status of the Network port.
•
Alarm
Displays the alarm value of the Network port. The unit
declares an alarm as soon as the count exceeds the threshold
set.
•
Count
Displays the number of events or occurrences of this statistic
that have been detected.
•
Threshold
A read/write field that can be set to a desirable threshold.