Verilink WANsuite 7205 (34-00317.B) Product Manual User Manual
Page 171

V T 1 0 0 I n t e r f a c e
4-49
Pattern Sync
Displays the state of pattern sync during a test. If no test is in progress, “No
Test” is displayed. If a test is active, but the receiver is not in pattern sync,
“No Sync” is displayed. If the receiver is in pattern sync, “In Sync” is
displayed.
Elapsed Time
Displays the time elapsed since a timed test began or, if completed, the total
test time.
Bit Errors
Displays the total number of bit errors detected since the test began or since
error statistics were cleared.
Errored Seconds
Displays the number of asynchronous errored seconds detected since the test
began or since error statistics were last cleared.
%EFS
Displays the percentage of time that the test ran error-free. This ratio is
derived from the number of error-free seconds divided by the number of
seconds accumulated in Elapsed Time.
Loop Table on Network Interface Test Details Screen
The Loop Table at the bottom of the screen lets you specify the type of Loop
test to be performed. The types of tests available for the Network interface are
shown below. Loopback diagrams are illustrated in Appendix A, Figure A.1.
Values: No Test (Loop Down), line loopback (LLB), maintenance
loopback (MLB)
Default: No Test (Loop Down)
Figure 4.42
Serial Interface Test Details Screen
BERT Table on Serial Interface Test Details Screen
The BERT table lets you set the test parameters listed below.