1

0

1

All outputs are zeroes

2

1

0

All outputs are ones

3

1

1

Continuous stream of ‘10’


ADCB Register 2 – 0x7.
For more details, refer to ADS5500 datasheet.

ADCB Register 2 – 0x7

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

1

Reserved PDN

Reserved

Default

‘000’ ‘0’

‘000’

0

Reserved

Default

‘00000000’

ADCB Register 2 – 0x7

Setting

PDN

Description

0

0

Normal Mode of Operation

1

1

Device in Power Down Mode


DAC Register 0 – 0x8.
For more details, refer to DAC5686 datasheet.

DAC Register 0 – 0x8

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

atest Version

Default

‘000000’ ‘000’

1

Freq_int[7:0]

Default

‘00000000’


DAC Register 1 – 0x9.
For more details, refer to DAC5686 datasheet.

DAC Register 1 – 0x9

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Freq_int[15:8]

Default

‘00000000’

1

Freq_int[23:16]

Default

‘00000000’