Sundance SMT350 User Manual
Page 12
Version 1.9
Page 12 of 45
SMT350 User Manual
ADC Channels.
ADC Main Characteristics.
The main characteristics of the SMT350 ADCs are gathered into the following table.
Analogue Inputs
Input voltage range
2.4 Vp-p (11.5 dbm – 50 Ohm) Full scale -
AC coupled
Impedance
ADC single-ended inputs are to be
connected to a 50
Ω source. Source
impedance matching implemented between
RF transformers and ADC.
Bandwidth
ADC bandwidth: 750 MHz.
ADCs Output
Output Data Width
14-Bits
Data Format
2’s Compliment or offset binary
(Changeable via control register)
SFDR
82dBs maximum (manufacturer)
SNR
70dBs maximum (manufacturer)
Minimum Sampling Clock
10 MHz (ADC DLL off)
Maximum Sampling Frequency
125 MHz (ADC DLL on)
Figure 3 - Main features.
ADC Input Stage.
Each ADC Analogue input is AC-coupled via and RF transformer. The 50-Ohm
resistor between the connector and the first RF transformer is not fitted because the
source impedance match is implemented between the second RF transformer and
the ADC by the way of two 25-Ohm resistors.
Figure 4 - ADC Input Stage.