Sundance SMT350 User Manual
Page 28

Version 1.9
Page 28 of 45
SMT350 User Manual
Test Register – 0x1.
Any 8-bit value written in this register can be read-back to check that the Comport
used works properly.
Test Register – 0x1
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
ADCA Register 0 – 0x2.
For more details, refer to ADS5500 datasheet.
ADCA Register 0 – 0x2
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
Reserved
Default
‘0000000’
0
Reserved PLL
Reserved
Default
‘000000’ ‘0’
‘0’
ADCA Register 0 – 0x2
Setting
Bit 1
Description
0
0
PLL OFF – for sampling frequencies between 10 and 80 MHz
1
1
PLL ON – for sampling frequencies between 60 and 125 MHz
ADCA Register 1 – 0x3.
For more details, refer to ADS5500 datasheet.
ADCA Register 1 – 0x3
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
Reserved TP1
TP0
Reserved
Default
‘00000’
‘0’ ‘0’ ‘0’
0
Reserved
Default
‘00000000’
ADCA Register 1 – 0x3
Setting
TP1
TP0
Description
0
0
0
Normal Mode of Operation
1
0
1
All outputs are zeroes
2
1
0
All outputs are ones
3
1
1
Continuous stream of ‘10’