Source Properties Window
Source Properties for a selected tile can be opened from the Module > Setup Source
menu, or by double-clicking on a selected source in the source folder.
Audio Tab
Use this tab to assign audio channels to sources and make various global settings for
phase bars and select reference levels for analog audio and analog scales.
Audio Mode - selects the audio source; Embedded (from SDI video), External (from
optional external audio input card), or AM-xx (audio over LAN. A list of available servers
appears in the drop-down box below).
Channel 1 to 16 Controls - select an audio input to display for the associated source
bar.
Phase Bar 1 and 2 – enable either or both phase bars and select two channels from the
appropriate drop down box.
Reset Button – press this button to reset all items in Channel/Phase bar drop-down lists
to the first available item (which will be "None" in the list given by the protocol).
A/D Reference – set the analog to digital reference level when applying an analog meter
scale to a digital source, or a digital meter scale to an analog source. It can be set within
the range of -30 to -3 dBfs.
0 dB Reference – set the 0dBu reference level with respect to analog meter scales. It
can be set within the range of -12 to +12 dB.
Note:
Neither the A/D or the 0dB reference adjustments have any effect when digital audio is
used with a digital scale.