5
LTC: In this mode the time is sourced from the LTC input on the rear of the frame. There is
nothing to setup here; there just needs to be LTC present for this to work properly. If no LTC is
present then the system clock will be used. (If LTC is present but later disappears then the clock
will continue advancing without any discontinuity).
VITC: Here the time can come from VITC that is present on any SDI input. Select the chosen SDI
source number that contains VITC. If no VITC is present then the system clock will be used. (If
VITC is present but later disappears then the clock will continue advancing without any
discontinuity).
Genlocking
Genlocking of the MV-xx is via SD colour black or HD tri-level sync, using the genlock input.
Using GPI I/O
Assignable GPI I/O with 16 inputs and 8 outputs for external alarm indication and recall of
predetermined video channels or screen configurations.
Bargraph scales
The following audio scales are supported:
Break points and colors used for the upper and lower ranges of each bar type can be customised
to satisfy any in-house monitoring style for each of the six scale types.