EH330, EH430 and ECC Condensing Unit

Remote Low Side Cuber Service Manual

July 2013

Page 43

Refrigeration Data

0

10

20

30

40

50

60

ECC1200 with EH330 90/90/70

Freeze Cycle Low Side Pressure

in PSIG

Discharge pressure at 90/70 will peak at 280 - 290 PSIG and drop to 160 during harvest.

Typical cycle time is 12 to 13 minutes, including 1 minute for harvest.

0

10

20

30

40

50

60

ECC1410 with EH430 90/90/70

Freeze Cycle Low Side Pressure

in PSIG

Discharge pressure at 90/70 will peak at 280 - 290 PSIG and drop to 160 during harvest.

Typical cycle time is 12 to 13 minutes, including 1 minute for harvest.