EH330, EH430 and ECC Condensing Unit

Remote Low Side Cuber Service Manual

May 2015

Page 2

Configuration

A remote low side cuber system includes two

sub systems: an ice head section and a remote

condensing unit. Additionally, there are several

models of each sub-system and this manual covers

all of them.

The ice making sections are designed for use indoors

in a controlled environment. The remote condensing

units are designed to operate outdoors. Each sub-

system has limits for power, water and temperature.

Operational Limitations:

Minimum

Maximum

Air Temp (IH)

50

o

F

100

o

F.

Air Temp (CU)

-20

o

F.

120

o

F.

Water Temp

40

o

F.

100

o

F.

Water Pressure

20 psi

80 psi

Water Conductivity

10

microSiemens/cm

Voltage (IH)

104

126

Voltage (CU)

198

253

IH = Ice Head, CU= Condensing Unit

Do Not operate the machine in conditions beyond

these limitations. Doing so will void the warranty.

Scotsman ice systems are designed and

manufactured with the highest regard for safety and

performance. They meet or exceed the standards of

UL and NSF.

Scotsman assumes no liability of responsibility of

any kind for products manufactured by Scotsman

that have been altered in any way, including the use

of any part and/or other components not specifically

approved by Scotsman.

Scotsman reserves the right to make design changes

and/or improvements at any time. Specifications and

design are subject to change without notice.

System Information

Warranty
Refer to the warranty coverage in effect when the

equipment was sold. Warranty statements are

included with each product.

Systems:
Each sub-system is a separate entity that carries

its own model and serial number. They must be

combined to create a remote cuber low side system.

System Size

Condensing Unit (CU)

Ice Making Head (IH)

Model

Electrical

(volts/Hz/phase)

Model

Electrical

(volts/Hz/phase)

1200

ECC1200-32A 208-230/60/1

EH330SL-1C/D or EH330ML-1C/D 115/60/1

1400

ECC1410-32A 208-230/60/1

EH430SL-1C/D or EH430ML-1C/D 115/60/1

1400

ECC1410-3A

208-230/60/3

EH430SL-1C/D or EH430ML-1C/D 115/60/1

1800

ECC1800-3A

208-230/60/3

EH430SL-1C/D or EH430ML-1C/D 115/60/1

Notes: Voltage Codes are at the end of the model

number. Codes read Voltage/Hertz/Phase. Those

related to these products include:

-1 = 115/60/1

-3 = 208-230/60/3

-32 = 208-230/60/1

Tubing kits are required to interconnect the head to

the CU

• 20 foot: 3BRTE20-EH,

• 35 foot: 3BRTE35-EH

• 50 foot: 3BRTE50-EH

• 75 foot: 3BRTE75-EH

Interconnecting 24 volt control wire ships in the

condensing unit.