beautypg.com

Freeze cycle sequence of operation – Scotsman EH330 C with ECC Condensing Unit ECC1200 User Manual

Page 37

background image

EH330, EH430 and ECC Condensing Unit

Remote Low Side Cuber Service Manual

July 2013

Page 36

Freeze Cycle Sequence of Operation

This sequence begins with a restart after the unit has

shut off with the bin full. Ice has been consumed,

causing the ice sensors to become un-blocked.

1. The controller (four minutes has to have passed

since the machine shut off on bin full for the machine

to restart)

2. The purge valve is opened and the pump started.

3. After the purge valve closes the inlet water valve

opens and fills the reservoir.

Note: If the water reservoir does not fill within the time

period expected the controller will shut off and switch

on the water indicator light. It will re-try to fill the

reservoir in 20 minutes. If successful the freeze cycle

will continue.

4. The compressor and fan motor start and the

freezing process begins.

Note: The controller is connected to two external

relays in the EH head, one for the condensing

unit’s compressor contactor and the other for the

its solenoid valves. A separate 24 volt transformer

is in the condensing unit supplying power to the

contacts of these two line voltage relays through the

interconnecting wire.

5. The controller will shut the water pump off for a

few seconds when the reservoir’s water temperature

reaches a pre-set point.

6. The freeze cycle continues until water makes

continuous contact with the ice thickness sensor. That

signals the controller to terminate the freeze cycle and

begin the harvest cycle. The Ready to Harvest light

will

be ON.