beautypg.com

Controller operation – Scotsman EH330 C with ECC Condensing Unit ECC1200 User Manual

Page 40

background image

EH330, EH430 and ECC Condensing Unit

Remote Low Side Cuber Service Manual

July 2013

Page 39

Controller Operation

Control Button Use (from standby - status light off)

Set purge level, 1-5 (1 is minimum, 5 is maximum) or

Automatic:
• Hold off button in for 3 seconds. Release.
• Press and release the On button to cycle through

and select one of the five purge settings or to use

the automatic setting.

Recall diagnostic code:
• Hold off button in for 3 seconds. Release.
• Press and release the Harvest button to cycle

through each of the last 10 error codes from most

recent to oldest.

Clear diagnostic code:
• Hold Clean and Harvest buttons in for 3 seconds

to clear all prior codes.

Reset control:
• Depress and release Off, then depress and

release On

Start Test Mode:
• Hold Off button in for 3 seconds. Release.
• Hold Clean button in for 3 seconds. Release.
Lock / Unlock control:
• Hold On button in for 3 seconds, keep holding

then press and release Off twice.

Empty reservoir:
• Hold Clean button in for 3 seconds. Release.

Pump and purge valve will be ON for 30 seconds.

Repeat as needed.

Test Mode:
• Depress Off for 3 seconds, release. Then depress

Clean for 3 seconds.

• The sump will fill the first 30 seconds of the test.

If the sump is full it will overflow into the bin. At 30

seconds the Water Inlet Valve will shut off and the

Water Pump will turn on. You will be able to see

and hear the water running over the plates. After

10 seconds the Purge and Vapor Inlet Valves will

turn on. Water will be purging from the machine.

After 10 more seconds the compressor will start. 5

seconds later the VIV will close. The compressor

will run for a total of 20 seconds. After which

everything will turn off for 5 seconds. After that

time the VIV will open and you’ll be able to hear

the hissing as the pressure is equalized. After 10

seconds all will be off and the output test will be

complete.

Change De-Scale Notification Interval
• Like the others, this feature is accessible only

from standby (Status Light Off).

• Press and hold harvest button for 3 seconds.
• This will allow control to enter Time to Clean

Adjustment State.

• Display current time to clean months on 7

segment display.

• Pressing clean button repeatedly will cycle

through one of 4 possible settings:

6 months (4380 hours) (default)

5 months (3650 hrs)

4 months (2920 hrs)

3 months (2190 hrs)

This manual is related to the following products: