Service Diagnosis

Problem or Symptom

Possible Cause

Probable Correction

No ice

No power to ice making section

Restore power

No power to condensing unit

Restore power

No lights on controller

Check transformer

Unit manually switched off

Push and release the On button, ask

user why it was shut off

Power to both sections, controller reset,

but condensing unit does not operate

Interconnecting control wire discon-

nected, reconnect it
Low or high pressure cut outs open,

check system pressures

No power to compressor contactor coil.

Check toggle switch in condensing

unit.
Check EH head compressor relay.

No water to ice making section, controller

blinking water light

Restore water supply, check water

filters, reset controller
Check inlet water valve operation
Check water level sensor

Ice making section has exceeded

maximum freeze time and controller has

shut down the system

Condenser coils may need cleaning
Check condenser fan blade and

motor
Check for excessive air intake tem-

peratures at condenser coil
Check compressor contactor
Check compressor and starting

components
Check water pump
Check purge valve for leak through
Check vapor inlet valve for leak

though

Ice making section has exceeded maxi-

mum harvest time and shut down the

system

Check ice making section for lime

scale build up, clean as needed
Check condenser by pass valve
Check vapor inlet valve
Check headmaster
Check curtain switch
Check inlet water valve for leak

through
Check for obstruction in ice delivery

chute

Condensing unit solenoids do not activate

during harvest

Check solenoid relay in EH head