Harvest Cycle Sequence of Operation

When harvest begins, the controller connects

power to the external relay for the condensing unit's

solenoids.

It also connects power to the vapor inlet solenoid

valves in the cabinet of the EH head.

The vapor inlet solenoid valves and the condenser

bypass valve open. The receiver inlet solenoid valve

closes. Vapor flows from the condensing unit to the

EH head evaporator inlets.

The water pump and purge valve will be on for a

period of time during the first part of harvest to purge

the water reservoir of a portion of the water.

The inlet water solenoid valve opens to fill the

reservoir when the water level sensor indicates an

empty sump. It continues to fill when the pump and

purge valve have shut off and will stop filling when the

water level sensor senses a full sump.

Harvest will continue until both curtains have opened.

The curtain switch, attached to the edge of each

curtain, will sense the curtain opening.

If the curtains both close, harvest will terminate and

the freeze cycle will resume.

If one or both of the curtains remains open for 30

seconds, the machine will shut down