EH330, EH430 and ECC Condensing Unit

Remote Low Side Cuber Service Manual

July 2013

Page 34

System Operation:

This section is intended for the technician. Understanding it is not necessary for the normal operation and

maintenance of this ice making system.

Major Components:

Ice making section sub-system:
• Controller,
• Water Level Sensor,
• Transformer,
• Evaporators,
• Expansion Valves
• Vapor Inlet Valves
• Water Pump,
• Inlet Water Valve
• Purge Valve.
• Harvest Assist Solenoid
Condensing Unit
• Compressor,
• Contactor,
• Condenser Bypass Valve,
• Liquid Inlet Valve,
• Receiver,
• Accumulator,
• CPR Valve,
• Headmaster.
• Coils
• Fan Motor
Freeze:

In the air cooled condensing unit sub-system the compressor is on, the condenser by-pass valve is closed, the

fan motor is rotating the fan blade.

Harvest:

During harvest the compressor and fan motor continue to operate. The vapor inlet, condenser bypass, receiver

inlet solenoid (normally open) and harvest assist solenoids are energized.

Ice releases and falls into the bin or dispenser.