Display menu

The parameters are selected using the rotary knob.
(HA = heating appliance)

System

Parameter

Function

Comments

Outdoor temp.

Displays the outdoor temperature

The measured outdoor temperature is smoothed for
the controller. The smoothed value is displayed here.

Actual/Target HA
temp.

Temperature of the heating appliance

After pressing the F-key, the target value appears.
The target value corresponds to the highest temperature
requested of the heating system by the consumer circuits
(incl. water heating). The mixer circuits request your
required temperature + heating curve distance (specialist
value)

Modulation

Modulation depth of the heating appliance
(bus)

Only if a modulating heating appliance is connected via
a bus and is transmitting values.

Burner 1

Burner relay 1 status (On/Off)

Burner 2

Burner relay 2 status (On/Off)

Error

Error number; 00 = no errors

This menu only activates the display itself. No adjustments can be made here. The values are only shown if the
sensor is connected or the values are available, otherwise “----” or nothing are displayed.
You can leave the menu by pressing “Cancel”.

Hot water

Parameter

Function

Comments

Actual/Target HW
temp.

Current hot water temperature and current
target hot water temperature depending on
heating programme and operating mode

Display of the measured upper tank temperature

Lower HW temp.

Lower HW tank temperature (infeed/solar)

Lower tank temperature
Only if a sensor is connected for the lower tank and
the charging function is activated

HW demand

Demand for water heating
On => Temperature not reached

Hot water status indicator

HW pump

Operation of hot water charging pump
On => e.g. after charge pump lock

Hot water status indicator

Enable HW

Enable water heating
On => Enable according to time programme

Hot water status indicator

9