Troubleshooting and customer service

The units and components are manufactured using state-of-the-art production methods and tested several times
to verify their correct function. However, if malfunctions should occur, please check the functions as detailed
in the list below. Please inform your dealer if the unit is still not working correctly after all function checks have
been performed!

Restart


1. Remove the battery and

turn the rotary knob.


2. Refit the battery.

Use the F-key [4] [Continue]

to ignore or cancel the

message “Bus code assigned”.

Restart / Reset

Reset

1. For individual parameters using

F-key [3] = [Default]


2. For the menus User, Specialist

or Time programmes, this can

be selected via the Service

menu, e.g. “Reset time

programme” menu item,

then adjusting the value from

Off to On with the rotary knob

and the pressing the F-key [4]

= [OK]. The unit restarts.


3. For the unit as a whole (incl. all

parameters), remove battery

and turn the rotary knob.

When reinserting the battery,

hold down the Home key.

Error

Possible cause

Checks

Remedial measures

Pumps do not switch off

Operating mode / settings
changed

Check operating mode /
settings

Check operating mode => Default
( set?). Check “HCP OPERATION”
setting value (default 00).

Pumps fail to switch on

Operating mode / time
and heating programme
/ pump switching /
heating thresholds /
room temperature-based
regulation changed

Check operating mode
/ time and heating
programme / pump
switching / heating
thresholds / room
temperature-based
regulation

Check operating mode => Default
( test).
Check time and heating programme
=> Heating period
Check pump switching => Type of
pump switching
Default => Outdoor temperature >
Room target temperature?
Heating thresholds => Outdoor
temperature > Valid heating limit?
Room-temperature-based regulation
=> Room temperature > Target
temperature + 1K
Additional test with the relay test
function of the controller.

Error number 81

Change in the tank of the
controller (e.g. due to EMC)

Check all settings values

Check all settings values, then
restart!

Other error numbers

Error caused by boiler or
mixer controller

Check the meaning of these
error in the corresponding
error tables

Look up the meaning in the boiler
error tables

Malfunctions

If the system does not operate
correctly, first check the cabling
in the controller and controller
components.
The wireless remote control must
be registered properly with a field
strength between 0 and (-80) dBm.
Bus connection (see Service menu)

In control panels on connection to
the mixer => Communication MM
= On
In control panels on connection
to the heating appliance =>
Communication KM = On
In the boiler controller on
connection to the control panel =>
Displays
the room temperature and
hides the current target room
temperature

General troubleshooting vinformation

“----” (see “Display/Heating
circuit”)
In the mixer expansion controller
on connection to the boiler
controller => Displays the outdoor
and the boiler temperature (see
“Display/System”) on the control
panel => Displays the room
temperature and hides the current
target room temperature “----”
(see “Display/Heating circuit”)

25