REMKO MHP-Manager Wireless Remote Control User Manual
Page 11

User menu
System
This menu contains all the settings which can be adjusted by the user of the system.
Parameter
Value range
Default
OV*)
Comments
Language
Depends on variant English
Set the language for the controller
LCD contrast
(-20) - (20)
04
Set the intensity of the display
LCD brightness
Off/On
On
Switch display backlight ON/OFF
LCD status
1 - 5
1
Since the display is the biggest consumer, while it is not
being operated, it switches into a power-saving mode (only
displaying the time and date).
In the interests of saving even more power to increase
battery life, the parameter [LCD Status] will switch off the
display altogether when the controller is in certain states:
1: Display ON
2: Display ON, with heating programme enabled
3: Display ON, if demand exists for heating
4: Display ON/OFF with time interval (10s OFF/ 5s ON)
5: Display OFF
If a control is operated, the display switches back on
automatically.
*) OV = Own values: space to enter you settings for each parameter in the system
Hot water
Parameter
Value range
Default
OV*)
Comments
1x hot water
Off/On
Off
On => The tank is enabled for charging (e.g. for showering
outside hot water time periods).
Charge begins when “Target temperature 1” is fallen below
by the switching hysteresis.
*) for KM1/6/9 and bus code 00/01 only
11