Remko wireless remote control, For multitalent heat pump manager – REMKO MHP-Manager Wireless Remote Control User Manual
Page 10

Heating circuit 1/2
Parameter
Function
Comments
Actual/Target room
temp.
Current room temperature according to
heating programme and operating mode
Room temperature and target room temperature
Actual/Target supply
temp.
Current supply temperature and
current target supply temperature
For mixed heating circuits only
Enable heating circuit Heating circuit in heating mode (On/Off)
Heating circuit status indicator
Heating circuit pump Heating circuit pump status (On/Off)
Heating circuit status indicator
R. warm-up time
Last required warm-up time
with warm-up optimisation activated
Display of the last required warm-up time
Parameter
Function
Comments
MF1 temp.
Temperature of MF sensor 1
A sensor is allocated to each multifunction relay.
The corresponding value is displayed here. In certain
cases, e.g. if the functions “Solid fuel boiler” or “Collector
pump” are selected, the measured value is also displayed
as the Solid fuel temp. or Collector temp.
MF2 temp.
Temperature of MF sensor 2
MF3 temp.
Temperature of MF sensor 3
MF4 temp.
Temperature of MF sensor 4
Actual/Target HW temp. Temperature of upper HW tank
Lower HW temp.
Lower HW tank temperature (infeed/solar)
Solar / MF
The following table only lists parameters for which the corresponding function has both been implemented and
activated
REMKO WIRELESS REMOTE CONTROL
FOR MULTITALENT HEAT PUMP MANAGER
10