Remko gpm, Safety information – REMKO GPM 15 User Manual
Page 4
![background image](https://www.manualsdir.com/files/802233/content/doc004.png)
4
REMKO GPM
Safety information
The units were subjected to
extensive material, function and
quality inspections and tests prior
to delivery. However, the units
may constitute a hazard if used by
untrained personnel, improperly or
not for the intended purpose.
The following information must be
observed:
■
The units must only be
operated by persons who have
been instructed in the operation
of the units
■
In the event of faults that affect
safe operation of the units, they
must be switched off
■
The units must be installed and
operated so that the discharging
hot air has no damaging
effects on the environment or
equipment
■
Do not expose the units to the
effects of weather (rain, sun,
etc.)
■
Do not touch the units with
moist or wet parts of the body,
e.g. hands
■
Protect the units from splashing
water or other liquids
■
Do not use gas pipes for
grounding electrical equipment
■
Do not touch hot parts of the
units such as the chimney pipe
■
Do not moving parts of the units
The units must always be operated in compliance with the applicable
local building and fire protection regulations and regulations of the
employers‘ liability insurance associations.
■
Never insert foreign objects in
the units
■
The units must only be mounted
on constructions or ceilings
of flame retardant materials
designed to take the weight
■
The units must only be fastened
at the points provided at the
factory
■
The units must not be installed
and operated in locations
exposed to fire hazards
and potentially explosive
atmospheres
■
The units must be installed
outside traffic zones, e.g. of
cranes. A protective zone of 1 m
distance must be maintained
■
The air inlets including grilles
must be kept free of dirt and
loose objects at all times
■
The units must not be exposed
to a direct jet of water
■
The units must be tested at least
once a year by a specialist
■
Safety devices must not be
overridden or blocked!
■
Before carrying out
maintenance or repairs, the gas
supply must be shut-off and the
unit disconnected in all poles
from the mains supply.
(Unscrew fuse or switch off
local main/emergency switch)
Precautions if there is a smell
of gas
1. Immediately switch off the unit.
2. Close the gas shut-off valve(s).
3. Warn all persons potentially at
risk.
4. Open windows and doors.
5. Do not operate electrical
devices such as light switches or
electrical plug contacts.
6. If the room in which there is a
smell of gas cannot be entered,
immediately call the fire brigade,
police and if necessary the
responsible gas supply company.
The units are intended
exclusively for industrial and
commercial use. They are not
intended for domestic heating
or similar..
NOTE
ATTENTION
Installation, adjustments and
maintenance must only be
carried out by authorised
specialists.
The safety devices must not be
overridden or blocked during
operation.
ATTENTION