Further week days can now
be programmed individually as
previously described or by copying.
The procedure for copying is as
follows:
Copy the already programmed day
with the K3
cop
button and press
the K1
tag
button.
Press the K3
cop
button
and the
K1
tag
button again.
Repeat this procedure for each
further week day with the same
data.
NOTE
All times indicated without
bars run automatically in the
night temperature zone
t1.
Continuous mode
In this mode, the control operates
continuously at a set room
temperature.
Settings can be programmed as
follows:
Press the KM button,
HZG
appears
on the left in the text bar.
K4
K3
K2
K1
KM
K-
K+
HZG san info
K4
K3
K2
K1
KM
K-
K+
auto on off uhr
Press the K1
hzg
button, the
following display appears.
Press the K2
ON
button, the
following display appears.
K4
K3
K2
K1
KM
K-
K+
temperatur
man
24,0
K4
K3
K2
K1
KM
K-
K+
temperatur
man
24,0
Set the flashing temperature indi-
cation to the required value with
the K+ and K- buttons.
By pressing the KM button, the
mode is permanently activated.
The basic display now appears
without timer bar.
K+
K-
KM
K1
K2
K3
K4
4
6
8
10 12 14 16 18 20 22 24
2
09:50
di
25,0
Manual mode
While the temperature control is in
the automatic mode, the required
room temperature can be changed
at any time by pressing the K+ or
K-
buttons.
Press the K+ or K- button, the
following display appears.
Set the flashing temperature
indication to the required value
with the K+ and K- buttons.
By pressing the KM button, the
mode is activated and indicated on
the display with a hand symbol.
This setting is automatically ended
again at the next programmed
switching point.
Press the K4 t3 button and with
the K+ button set the flashing
cursor in the top bar from the
position 7
00
to 12
00
.
In the position from 7
00
- 12
00
a
full bar is displayed.
Exit the temperature level t3 with
the K2 reg button.
Press the K3 t2 button and with
the K+ button move the flashing
cursor from 12
00
- 14
00
.
In the position from 12
00
- 14
00
half a bar is displayed.
Exit the temperature level t2 with
the K2 reg button.
Press the K4 t3 button and with
the K+ button set the flashing
cursor in the top bar to the
position 17
00
.
In the position from 14
00
- 17
00
a full bar is displayed. Exit the
temperature level t3 with the K2
reg
button.
K4
K3
K2
K1
KM
K-
K+
tag reg cop vor
4
6
8
10 12 14 16 18 20 22 24
2
13:00
mo
NOTE
The automatic mode can
be selected prematurely by
pressing the
KM
button, the
K1
hzg
button and the
K1 auto
button.
NOTE
The automatic mode can be
reselected by pressing the
KM
,
button, the
K1
hzg
button and
the
K1 auto
button.