Remko gpm, Timer, Temp – REMKO GPM 15 User Manual

Page 18: Auto, Reset

background image

18

REMKO GPM

K4

K3

K2

K1

KM

K-

K+

HZG san info

Press the K1

hzg

button, the

following display appears.

Timer mode

In this mode, the temperature con-
trol operates within a fixed time
window.
Press the KM button,

HZG

appears

on the left in the text bar.
Press the K1

HZG

button and in the

following display press the K4

uhr

button.
In the following display, set the
flashing time/hour indication to
the required value with the K+ or
K-

button.

K4

K3

K2

K1

KM

K-

K+

timer

4

6

8

10 12 14 16 18 20 22 24

2

17:00

fr

24,0

The timer mode is indicated in the
display with

timer

.

The timer can be set up to 12
hours in 30 minute steps.

After lapse of the timer program-
med time, the unit switches back
to the automatic mode again.

K4

K3

K2

K1

KM

K-

K+

dauer

temp

20,0

02:00

Press the K4

temp

button and set

the flashing temperature indication
to the required value with the K+
or K- button.
Press the KM button to return to
the operational display.

Fault message display

The temperature control ATR-6
can display possible system faults
and supply diagnostic information.
Possible Unit faults are indicated
by a flashing triangle and ”Reset
heating”

in the following display.

!

K4

K3

K2

K1

KM

K-

K+

reset

4

6

8

10 12 14 16 18 20 22 24

2

08:25

di

18,5

kessel

!

K4

K3

K2

K1

KM

K-

K+

fehlercode

!

1

Faulty code analysis is described in
the chapter “Troubleshooting” in
the operating instructions.

By pressing the K4 (>>) button,
the fault code (e.g. 1) is displayed.

NOTE

After 5 unsuccessful reset att-
empts, the control electronics
of the unit are permanently
locked.
In order to restart the unit, it
must be disconnected from the
mains supply.

NOTE

The timer program can be
ended prematurely by pressing
the

KM

button, the

K1

hzg

but-

ton and the

K1

auto

button.

NOTE

The heating program can be
reactivated by pressing the

KM

button, the

K1

hzg

button and

the

K1

auto

button.

Prior to troubleshooting and
clearing faults, no reset must be
performed.

ATTENTION

K4

K3

K2

K1

KM

K-

K+

auto on off uhr

Switch off the unit

Press the KM button,

HZG

appears

in the text bar.

K4

K3

K2

K1

KM

K-

K+

13:50

fr

20,0

NOTE

In this mode, frost protection
is automatically activated at a
temperature of 5°C.

Press the K3

off

button, the fol-

lowing display and symbol appear.

After locating and clearing the
fault, the unit must be reset via the
K1

reset

button.