Remko gpm, Program example, Prog – REMKO GPM 15 User Manual
Page 16: Reg san
16
REMKO GPM
Automatic mode
In this program, the temperature
control controls the wall gas heater
fully automatically.
The room temperature, week day
and current time in hours and
minutes are indicated permanently
on the LCD display.
Program example:
Programming a day temperature
(T3) of 20.5°C Monday to Friday
from 7
00
- 17
00
.
Programming a medium
temperature of 18°C lunch time
from 12
00
- 14
00
.
Programming a night temperature
(reduction temperature) of 15°C
from 17
00
- 7
00
.
Programming a continuous night
temperature (T1) of 15°C from
Saturday to Sunday.
Settings can be programmed as
follows:
Press the KM button,
HZG
appears
on the left in the text bar.
K4
K3
K2
K1
KM
K-
K+
prog reg uhr
K4
K3
K2
K1
KM
K-
K+
prog reg uhr
Make a selection with the K1
prog
button. The following display
appears.
K4
K3
K2
K1
KM
K-
K+
tag reg cop vor
4
6
8
10 12 14 16 18 20 22 24
2
13:00
mo
Press the K1
tag
button
repeatedly to select the week day
(e.g. Monday).
Make a selection with the K2
reg
button, the temperature windows
T1 and T3 appear.
K4
K3
K2
K1
KM
K-
K+
t1
t2
t3
..
Press the K4 button (>>), the
following display appears.
Existing settings must always
first be deleted on
Level
T1
with
the
K+ and K- buttons.
Position the cursor on the
clock from where the program
is to be started on the next
temperature window (e.g. 7
00
).
No corrections (overwrite) can
be made on levels
T2
and
T3
.
ATTENTION
Press the K2
reg
button, the
following display with the
temperature window T3 appears.
K4
K3
K2
K1
KM
K-
K+
tem raum t1
10,0
REG SAN Value
By pressing the K4 (>>) button
twice again (after the temperature
window 3), the
Reg san
display
appears.
Adjust the flashing temperature
indication appropriate to the unit
installation with the K+ and K-
buttons.
See the table under the section
“Modulation” (page 9) in these
operating instructions.
Programming can be ended by
pressing the KM button.
The temperature control has 3
temperature windows.
T1
= Reduction temperature
(night)
T2
= Medium temperature
T3
= Day temperature
The procedure for setting and
changing is as follows:
Press the KM button,
HZG
appears
on the left in the text bar.
Press the K4 (>>) button, the
following display appears.
With the K+ and K- buttons select
the required temperature (e.g.
15°C) for the temperature window
T1.
Press the K4 (>>) button to display
the temperature window T2.
With the K+ and K- buttons set
the required temperature (e.g.
18°C) for T2.
Press the K4 (>>) button to display
the temperature window T3. With
the K+ and K- set the required
temperature (e.g. 20.5°C) for T3.
Setting temperature window and REG SAN value