beautypg.com

ONICON F-2600 User Manual

Page 121

background image

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]

F-2600 & F-2700 Vortex Flow Meter Manual 02/15 - 0808-7 / 19204

Page A-9

METER ORDERING INFORMATION

Insertion Vortex Meter Codification = F-2700-ABC-DEFG

A = Connection Type
0 = 2” Male NPT threads with retractor
1 = 2” ANSI class 150 flange with retractor
3 = 2” ANSI class 300 flange with retractor
6 = 2” ANSI class 600 flange with retractor
7 = 2” Male NPT threads without retractor (

≤50psig maximum pressure)

8 = 2” ANSI class 150 flange without retractor (

≤50psig maximum pressure)

9 = 2” ANSI class 300 flange without retractor (

≤50psig maximum pressure)

B = Integral or Remote Mount Transmitter

1

=

Integral

Mount

2

=

Remote

Mount

C = Temperature / Pressure Compensation
0

=

Integral

temperature

compensation

1 = Integral temperature & pressure sensor, 30 psia maximum
2 = Integral temperature & pressure sensor, 100 psia maximum
3 = Integral temperature & pressure sensor, 300 psia maximum
4 = Integral temperature & pressure sensor, 500 psia maximum
9

=

None

D = Input Power
0 = Loop powered (Only available with Output Signals option F=0)
1

=

External

12-36

VDC

powered

2

=

External

85-240

VAC

powered

E = Output Signals
0 = 4-20mA output*, pulse output & frequency output
1 = 4-20mA output, pulse output & frequency output, alarm output & MODBUS
2 = 4-20mA output, pulse output & frequency output, alarm output & BACnet
3 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & MODBUS
4 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & BACnet
5 = (3) 4-20mA outputs*, (3) alarm outputs, (1) pulse output (1) frequency output
6 = 4-20mA output*, pulse output & frequency output, alarm output

F = Maximum Operating Temperature
0 = 500° F
1

=

750°

F

G = Energy Meter

0

=

None

1

=

Gross

energy

meter

2 = Net energy meter (requires additional remote temperature sensor.)

*

Available

with

HART

®

serial communications

Remote Temperature Sensor and Thermowell Installation Kit

(Required for Net Energy Meter)

Part Number

Description

20100

Remote Temperature Sensor, 1,000 Ohm 4-wire Class A Platinum RTD

20101

Remote Thermowell Kit for 1½" Welded Steel Pipe

20102

Remote Thermowell Kit for 2 - 5" Welded Steel Pipe

20103

Remote Thermowell Kit for 6 - 14" Welded Steel Pipe

Note: Net energy meter requires 1 temperature sensor and 1 thermowell installation kit sized to pipe.

This manual is related to the following products: