APPENDIX A PRODUCT SPECIFICATIONS
Accuracy
Process
Variables
In-Line Meters
Insertion Meters
(1)
Liquids
Gas & Steam
Liquids
Gas & Steam
Mass Flow
Rate
±1% of rate
over a 30:1 range
(3)
±1.5% of rate
(2)
over
a 30:1 range
(3)
±1.5% of rate over
a 30:1 range
(3)
±2% of rate
(2)
over a 30:1 range
(3)
Volumetric
Flow Rate
±0.7% of rate over
a 30:1 range
(3)
±1% of rate
over a 30:1 range
(3)
±1.2% of rate over
a 30:1 range
(3)
±1.5% of rate over a
30:1 range
(3)
Temperature
±2° F
(±1° C)
±2° F
(±1° C)
±2° F
(±1° C)
±2° F
(±1° C)
Pressure
0.3% of transducer
full scale
0.3% of transducer
full scale
0.3% of transducer
full scale
0.3% of transducer
full scale
Density
0.3% of
reading
0.5% of
reading
(2)
0.3% of
reading
0.5% of
reading
(2)
Notes:
(1) Accuracies stated are for the total mass flow through the pipe.
(2) Over 50 to 100% of the pressure transducer’s full scale
(3) Nominal rangeability is stated. Precise rangeability depends on fluid and pipe size.
Repeatability
Mass Flow Rate: 0.2% of rate
Volumetric Flow Rate: 0.1% of rate
Temperature: ± 0.2° F (± 0.1° C)
Pressure: 0.05% of full scale
Density: 0.1% of reading
Stability Over 12 Months
Mass Flow Rate: 0.2% of rate maximum
Volumetric Flow Rate: Negligible error
Temperature: ± 0.1° F (± 0.5° C) maximum
Pressure: 0.1% of full scale maximum
Density: 0.1% of reading maximum
Response Time
Adjustable from 1 to 100 seconds
Material Capability
In-Line Flow Meter:
Any gas, liquid or steam compatible with 316L stainless steel, C276
hastelloy or A105 carbon steel. Not recommended for multi-phase
fluids.
Insertion
Flow
Meter:
Any gas, liquid or steam compatible with 316L stainless steel. Not
recommended
for
multi-phase
fluids.
Flow Rates
Typical mass flow ranges are given in the following table. Precise flow
depends on the fluid and pipe size. F-2700 insertion meters are applicable to
pipe sizes from 2" and above. Consult the factory for sizing program.
Water Minimum and Maximum Flow Rates
½"
¾"
1"
1½"
2"
3"
4"
6"
8"
15 mm
20 mm
25 mm
40 mm
50 mm
80 mm
100 mm
150 mm
200 mm
gpm
1
22
1.3
40
2.2
67
5.5
166
9.2
276
21
618
36
1076
81
2437
142
4270