beautypg.com

ONICON F-2600 User Manual

Page 113

background image

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]

F-2600 & F-2700 Vortex Flow Meter Manual 02/15 - 0808-7 / 19204

Page A-1

APPENDIX A PRODUCT SPECIFICATIONS

Accuracy

Process

Variables

In-Line Meters

Insertion Meters

(1)

Liquids

Gas & Steam

Liquids

Gas & Steam

Mass Flow

Rate

±1% of rate

over a 30:1 range

(3)

±1.5% of rate

(2)

over

a 30:1 range

(3)

±1.5% of rate over

a 30:1 range

(3)

±2% of rate

(2)

over a 30:1 range

(3)

Volumetric

Flow Rate

±0.7% of rate over

a 30:1 range

(3)

±1% of rate

over a 30:1 range

(3)

±1.2% of rate over

a 30:1 range

(3)

±1.5% of rate over a

30:1 range

(3)

Temperature

±2° F

(±1° C)

±2° F

(±1° C)

±2° F

(±1° C)

±2° F

(±1° C)

Pressure

0.3% of transducer

full scale

0.3% of transducer

full scale

0.3% of transducer

full scale

0.3% of transducer

full scale

Density

0.3% of

reading

0.5% of

reading

(2)

0.3% of

reading

0.5% of

reading

(2)

Notes:

(1) Accuracies stated are for the total mass flow through the pipe.
(2) Over 50 to 100% of the pressure transducer’s full scale
(3) Nominal rangeability is stated. Precise rangeability depends on fluid and pipe size.

Repeatability

Mass Flow Rate: 0.2% of rate

Volumetric Flow Rate: 0.1% of rate

Temperature: ± 0.2° F (± 0.1° C)

Pressure: 0.05% of full scale

Density: 0.1% of reading

Stability Over 12 Months

Mass Flow Rate: 0.2% of rate maximum

Volumetric Flow Rate: Negligible error

Temperature: ± 0.1° F (± 0.5° C) maximum

Pressure: 0.1% of full scale maximum

Density: 0.1% of reading maximum

Response Time

Adjustable from 1 to 100 seconds

Material Capability

In-Line Flow Meter:

Any gas, liquid or steam compatible with 316L stainless steel, C276

hastelloy or A105 carbon steel. Not recommended for multi-phase

fluids.

Insertion

Flow

Meter:

Any gas, liquid or steam compatible with 316L stainless steel. Not

recommended

for

multi-phase

fluids.

Flow Rates

Typical mass flow ranges are given in the following table. Precise flow

depends on the fluid and pipe size. F-2700 insertion meters are applicable to

pipe sizes from 2" and above. Consult the factory for sizing program.

Water Minimum and Maximum Flow Rates

½"

¾"

1"

1½"

2"

3"

4"

6"

8"

15 mm

20 mm

25 mm

40 mm

50 mm

80 mm

100 mm

150 mm

200 mm

gpm

1

22

1.3

40

2.2

67

5.5

166

9.2

276

21

618

36

1076

81

2437

142

4270

This manual is related to the following products: