METER ORDERING INFORMATION

Vortex Meter Codification = F-26AAaa-BCD-EFGH

AAaa = Meter Size in Inches
0500

=

½”

0400

=

4”

3400

=

¾”

0600

=

6”

0100

=

1”

0800

=

8”

1500

=

1½”

1000

=

10”

0200

=

2”

1200

=

12”

0300

=

3"

B = Connection Type
0

=

Wafer

1 = ANSI Class 150 flange

3 = ANSI Class 300 flange

6 = ANSI Class 600 flange
C = Integral or Remote Mount Transmitter
1

=

Integral

Mount

2

=

Remote

Mount

D = Temperature / Pressure Compensation
0

=

Integral

temperature

compensation

1 = Integral temperature & pressure sensor, 30 psia maximum

2 = Integral temperature & pressure sensor, 100 psia maximum

3 = Integral temperature & pressure sensor, 300 psia maximum

4 = Integral temperature & pressure sensor, 500 psia maximum

9

=

None

E = Input Power
0 = Loop powered (Only available with output signals option F=0)

1

=

External

12-36

VDC

powered

2

=

External

85-240

VAC

powered

F = Output Signals
0 = 4-20mA output*, pulse output & frequency output

1 = 4-20mA output, pulse output & frequency output, alarm output & MODBUS

2 = 4-20mA output, pulse output & frequency output, alarm output & BACnet

3 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & MODBUS

4 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & BACnet

5 = (3) 4-20mA outputs*, (3) alarm outputs, (1) pulse output (1) frequency output

6 = 4-20mA output*, pulse output & frequency output, alarm output

G = Maximum Operating Temperature

0 = 500° F

1

=

750°

F

H = Energy Meter
0 = None

1

=

Gross

energy

meter

2 = Net energy meter (requires additional remote temperature sensor)
*

Available

with

HART

®

serial communications

Remote Temperature Sensor and Thermowell Installation Kit

(Required for net energy meter)

Part Number

Description

20100

Remote Temperature Sensor, 1,000 Ω 4-wire Class A Platinum RTD

20101

Remote Thermowell Kit for 1½” Welded Steel Pipe

20102

Remote Thermowell Kit for 2” - 5” Welded Steel Pipe

20103

Remote Thermowell Kit for 6” - 14” Welded Steel Pipe

Note: Net energy meter requires one temperature sensor and one thermowell installation kit sized to pipe.