ONICON F-2600 User Manual
Page 115
11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
F-2600 & F-2700 Vortex Flow Meter Manual 02/15 - 0808-7 / 19204
Page A-3
Minimum and Maximum Saturated Steam Flow Rates @ Specific Operating Pressures
Pressure
Insertion Meter Flow Rates in lb / hr
Nominal Diameter (in), Schedule 40 Pipe
3
4
6
8
10
12
14
16
5 psig
205
2721
353
4685
800
10633
1385
18412
2184
29022
3099
41196
3746
49788
4893
65039
15 psig
248
3995
427
6880
969
15614
1679
27038
2646
42618
3756
60495
4539
73112
5930
95508
50 psig
357
8295
616
14284
1397
32417
2419
56135
3813
88481
5412
125597
6541
151792
9967
269822
75 psig
417
11288
718
19438
1629
44112
2822
76385
4447
120401
6313
170907
7630
206551
1470
39801
100 psig
468
14246
807
24532
1831
55674
3170
96407
4996
151960
7092
215703
8571
260691
11197
340546
150 psig
557
20111
958
34631
2175
78592
3766
136092
5936
214513
8426
304495
10184
368001
13303
480728
200 psig
632
25948
1089
44683
2470
101405
4278
175595
6743
276779
9572
392880
11568
474820
15111
620268
300 psig
762
37652
1311
64838
2976
147145
5153
254799
8123
401623
11530
570093
13935
688994
18203
900047
Linear Range
Smart electronics corrects for lower flow down to a Reynolds number of 5,000. The
Reynolds number is calculated using the fluid’s actual temperature and pressure
monitored by the meter. Rangeability depends on the fluid, process connections and
pipe size. Consult factory for your application. Typical velocity range ability in
standard applications is as follows:
Liquids 30:1
1 foot per second velocity minimum
30 feet per second velocity maximum
Gases 30:1
10 feet per second velocity minimum
300 feet per second velocity maximum
Process Fluid Pressure
In-Line Pressure Ratings
Process
Connection
Material
Rating
Flanged
316L SS, A105 Carbon Steel, C276 Hastelloy
150, 300, 600 lb, PN16, PN40, PN64
Wafer
316L SS, A105 Carbon Steel, C276 Hastelloy
600 lb, PN64