4 evaporator fan assembly, 5 wiring notice, 6 perform the inspection – MovinCool Classic 40 Service Manual User Manual
Page 73: Evaporator fan assembly, Wiring notice, Perform the inspection
![background image](https://www.manualsdir.com/files/799152/content/doc073.png)
Repair Section
73
9.4 Evaporator Fan Assembly
• Install evaporator fan. Allow a clearance of 0.06
in (1.5 mm) or more on side of the evaporator fan.
CAUTION
• Tightening torque:
- 13.3 ± 0.6 ft•lbf (18.0 ± 0.8 N•m)
9.5 Wiring Notice
• Secure the wires using clamps so that they do not come into contact with the edges of the
structure, etc. Secure the wires using clamps in the same position they were before removal.
9.6 Perform the Inspection
• Perform the inspection of cooling performance and check for abnormal noise or abnormal
vibration.
I002649
0.06 in
(1.5 mm)
or more
0.06 in
(1.5 mm)
or more
This manual is related to the following products: