beautypg.com

MovinCool Classic 40 Service Manual User Manual

Page 60

background image

Repair Section

60

5) Loosen the set bolt using a box wrench, and then

remove the evaporator fan.

CAUTION

• Set Bolt Torque Value (for Installation):

- 13.3 ± 0.6 ft•lbf (18.0 ± 0.8 N•m)

6) Take off the four (4) nuts, and then remove the

evaporator fan motor together with the inlet ring.

7) Take out the three (3) nuts, and then remove the

evaporator fan motor.

I002646

Set Bolt

Evaporator Fan

I002647

Nuts (4)

Inlet Ring

I002648

Nuts (3)

Fan Motor

Inlet Ring