Operation Section
27
5.4 Compressor
(1) Compressor motor
• The compressor motor is a single-phase motor
and is contained within the same housing as
the compressor.
(2) Compressor overload relay
• An external compressor overload relay is used
to protect the compressor motor. This relay is
mounted within the connector housing that
attaches to the top of the compressor. The
relay interrupts the flow of current when there
is an overload condition such as high current
draw and/or high temperature build up in the
compressor.
Operating Temperature
Non-Operating Limit at 212 °F
(100 °C)
Marking
OFF (Open Contacts)
ON (Closed Contacts)
302 °F (150 °C)
142 °F (61 °C)
12.8 A
MRA1261-12026
I002355
I001691
Bimetal
Terminal
Points
Specifications:
Rated Voltage
115 V
Rated Output
700 W