Press the PRINTER FEED button to align paper in Drive, then press
the PRINTER RESET button.
Active Program
Press this button in order to print the current weld procedure that is
loaded on the memory of the unit.
Last Orbital Weld
Press this button to obtain a printout of the last completed orbital weld.
This will give the same results as the PRINT WELD button on the WELD
ORBITAL screen.
This will give a weld procedure printout, first showing the description of
the procedure, followed by the all the welding parameters, then by Limit
and Deviation parameters, then by the actual strip chart of the weld am-
perage, arc voltage and motor speed.
Program List
Press this button to printout the complete listing of all the weld proce-
dures saved in the memory of the unit.
Calibration Report
To obtain a printout of the calibration values for the motor, motor-tachom-
eter feedback, current and voltage scales, press this button.
Print Option
This button controls the Deviation Report printout after each weld. There
are only three options available for this printout, they are as follows:
NEVER, ALWAYS & FAULTS.
In the NEVER mode, a printout of the weld will only occur if the
PRINT WELD button is pressed.
In the ALWAYS mode, at the end of every weld once the rotor returns
to the home position, it will automatically printout the resultant Strip
Chart as if the PRINT WELD button had been pressed.
In the FAULTS mode, a Strip Chart will only printout if there were
deviations in the weld sequence.
Section 13
Calibration Menu
Prior to using the CobraTig® 150 XM unit for welding, it is generally a good
idea to calibrate the output and feedback readings prior to striking an arc.