beautypg.com

MK Products CobraTig 150 XM User Manual

Page 14

background image

CobraTig 150 Owner's Manual P/N 091-0417 - Page 14

on the rear panel - see below). The unit will remember the last screen that

was on when it was powered off. To start from the beginning, it is best to

calibrate the weldhead prior to starting. Once the weldhead is calibrated,

press any button that will return the screen to the MAIN MENU.

From this point use the AUTO PROG button to start designing the weld pro-

cedure, enter the appropriate variables for the material to be welded, prepare

and align material to be welded, check for proper purge gas flow... Press

START.

The CobraTig® 150 XM unit will automatically prepurge the gas flow, initiate

the welding arc, perform any tacks if so desired, complete the weld in one or

multiple revolutions depending on procedure design and return the rotor to

home position while the postpurge gas is flowing. Weld complete.

Weldhead Connector

RS-232 Data Connector

The CobraTig®uses a DB-9 connector to communicate with an External PC.

The wiring for this plug is “cable/null” modem wiring (female connector both

ends).