Note: The Current High Amps establishes the maximum output in
amps that may be obtained.
· Press F5 or F10 and enter High current value from 0.2~150 amps.
· Press F4 or F9 and scroll to Curr. L. (A), low weld current in amps.
· Press F5 or F10 and enter Low current value from 0.2~150 amps.
· Press F4 or F9 and scroll to Pulse H. (S), high weld current pulse
time.
· Press F5 or F10 and enter High weld current pulse time from
0.00~0.99 seconds.
· Press F4 or F9 and scroll to Pulse L. (S), low weld current pulse
time.
· Press F5 or F10 and enter Low weld current pulse time from
0.00~0.99
seconds.
· Press F4 or F9 and scroll to Pre-Gas (S), pre-purge gas time.
· Press F5 or F10 and enter pre-purge gas time from 0.0~9.9 seconds.
· Press F4 or F9 and scroll to Post-Gas (S), post-purge gas time.
· Press F5 or F10 and enter post-purge gas time from 0.0~9.9
seconds.
· Press F4 or F9 and scroll to Strike (A), arc strike weld current.
· Press F5 or F10 and enter arc strike weld current from 0.1~25.0
amps.
· Press Foot Control to maximum and hold for duration of weld
· Press F6 Print Weld wave form graphics from integral printer
WELD MANUAL SCREEN DISPLAY
· F1, Start/Stop, used for manual Start/Stop operations without a foot
control.
· F2, Main Menu, returns to the Main Menu display.
· F3, Weld Orbital, returns to the Weld Orbital display.
· F4, Scroll UP, scrolls the highlighted field from one demand
parameter
to the next demand parameter.
· F5, Adjust Up, increases the numerical value of the demand
parameter selected. As this button is pressed for each parameter a
vertical bar graph displays the increasing value, both numerically and
graphically from the bar graph. For most parameters, a maximum
value is obtained once the vertical bar graph has reached the top of
the scale. Also, there is a change in the sound once the top of the
scale has been reached. The sound changes from a single beep to a
triple beep.
· F6, Print Weld, Data-Monitoring of manual weld produces a graphical
real time wave form of welding amps and arc volts.
· F7, Pedal On, selects the variable remote foot control for operation.
· F7, Pedal Off, selects the On/Off switch control and permits
additional programming of weld current Upslope time in seconds and
Final Slope weld current time in seconds.
· F8, Blank, no function control.
· F9, Scroll Down, scrolls the highlighted field from one demand
parameter to the next demand parameter.
· F10, Adjust Down, decreases the numerical value of the demand
parameter selected. As this button is pressed for each parameter a
vertical bar graph displays the decreasing value, both numerically
and graphically from the bar graph. For most parameters, a minimum
value is obtained once the vertical bar graph has reached the bottom
of the scale. Also, there is a change in the sound once the bottom of
the scale has been reached. The sound changes from a single beep
to a triple beep.
Section 8
Weld Orbital