beautypg.com

MK Products CobraTig 150 XM User Manual

Page 16

background image

CobraTig 150 Owner's Manual P/N 091-0417 - Page 16

Note: The Current High Amps establishes the maximum output in

amps that may be obtained.

· Press F5 or F10 and enter High current value from 0.2~150 amps.

· Press F4 or F9 and scroll to Curr. L. (A), low weld current in amps.

· Press F5 or F10 and enter Low current value from 0.2~150 amps.

· Press F4 or F9 and scroll to Pulse H. (S), high weld current pulse

time.

· Press F5 or F10 and enter High weld current pulse time from

0.00~0.99 seconds.

· Press F4 or F9 and scroll to Pulse L. (S), low weld current pulse

time.

· Press F5 or F10 and enter Low weld current pulse time from

0.00~0.99

seconds.

· Press F4 or F9 and scroll to Pre-Gas (S), pre-purge gas time.

· Press F5 or F10 and enter pre-purge gas time from 0.0~9.9 seconds.

· Press F4 or F9 and scroll to Post-Gas (S), post-purge gas time.

· Press F5 or F10 and enter post-purge gas time from 0.0~9.9

seconds.

· Press F4 or F9 and scroll to Strike (A), arc strike weld current.

· Press F5 or F10 and enter arc strike weld current from 0.1~25.0

amps.

· Press Foot Control to maximum and hold for duration of weld

· Press F6 Print Weld wave form graphics from integral printer

WELD MANUAL SCREEN DISPLAY

· F1, Start/Stop, used for manual Start/Stop operations without a foot

control.

· F2, Main Menu, returns to the Main Menu display.

· F3, Weld Orbital, returns to the Weld Orbital display.

· F4, Scroll UP, scrolls the highlighted field from one demand

parameter

to the next demand parameter.

· F5, Adjust Up, increases the numerical value of the demand

parameter selected. As this button is pressed for each parameter a

vertical bar graph displays the increasing value, both numerically and

graphically from the bar graph. For most parameters, a maximum

value is obtained once the vertical bar graph has reached the top of

the scale. Also, there is a change in the sound once the top of the

scale has been reached. The sound changes from a single beep to a

triple beep.

· F6, Print Weld, Data-Monitoring of manual weld produces a graphical

real time wave form of welding amps and arc volts.

· F7, Pedal On, selects the variable remote foot control for operation.

· F7, Pedal Off, selects the On/Off switch control and permits

additional programming of weld current Upslope time in seconds and

Final Slope weld current time in seconds.

· F8, Blank, no function control.

· F9, Scroll Down, scrolls the highlighted field from one demand

parameter to the next demand parameter.

· F10, Adjust Down, decreases the numerical value of the demand

parameter selected. As this button is pressed for each parameter a

vertical bar graph displays the decreasing value, both numerically

and graphically from the bar graph. For most parameters, a minimum

value is obtained once the vertical bar graph has reached the bottom

of the scale. Also, there is a change in the sound once the bottom of

the scale has been reached. The sound changes from a single beep

to a triple beep.

Section 8

Weld Orbital

This manual is related to the following products: