beautypg.com

MK Products CobraTig 150 XM User Manual

Page 13

background image

CobraTig 150 Owner's Manual P/N 091-0541 - Page 13

below. If it does not, turn CobraTig® 150 XM off and try again.

3. On the PC, while running DOS insert the diskette and change to drive

A:\. Type UPDAT150.EXE and press ENTER.

When prompted, type in the port number (see PC owner’s manual).

4. Once the upgrading program starts, the screen on the CobraTig® 150

XM will show the status of the downloading. Once complete, turn off the

CobraTig® 150 XM and disconnect RS-232 serial cable.

5. Restart the CobraTig® 150 and view the MAIN MENU to inspect for the

new SmartArc® software version number.

Section 5

OPERATION

To operate the CobraTig® 150 XM portable orbital welding unit, plug in any

standard MK Orbital weldhead to the rear panel, and perform the basic setup

procedures associated with collets, tungsten, and concentricity. Plug the Co-

braTig® 150 XM into any 120VAC electrical outlet (independent and isolated

circuits will produce the best results), connect the quick disconnect gas fitting

into the unit, and the other end to any argon flowmeter.

Power the unit on by rocking the ON/OFF switch to the ON position (located

Amphenol

Connector

Electrode

Ground

Weldhead Gas

ON/OFF

RS232

Input Gas

Input Power

Cable

Weldhead

Connections

This manual is related to the following products: