beautypg.com

MK Products Advanced Color Logic User Manual

Page 8

background image

Advanced Color Logic Owner’s Manual - Page 1

Section A

Installation

1. Technical Specifications

Electrical Characteristics:

Line Power:

120 VAC (± 10%), 50/60 Hz

208 - 240 VAC (± 10%), single phase, 50/60 Hz.

208 - 240 VAC (± 10%), three phase, 50/60 Hz.

Output Current:

1 to 200 amps (± 1.0%), constant or pulsed.

Pulse Rate:

0.01 to 9.99 seconds per pulse.

Arc Voltage:

80VDC open circuit, up to 20VDC during welding

Loop Response:

3KHz

Current Regulator
Frequency: 18KHz

Motor Control:

24V, 2 amp maximum, DC tachometer feedback or

back EMF (optional).

Mechanical Characteristics:

Width:

16.75 inches

Height:

16.25 inches

Depth:

27.5 inches

Weight:

110 lbs. (ACL only)

Shipping Weight:

350 lbs. (includes ACL, monitor, printer, keyboard,

power cable and Customer Start-Up Kit; palletized)

Computer Control System:

Microcomputer
Architecture:

Embedded operating system.

Computer Memory: AMD Athlon 2200+ or faster. 128MB or more DRAM

memory. 1MB static RAM for weld procedure storage.

Floppy drive for procedure back-up, transfer, real time

logging & program upgrade.

Program storage: 1000 procedures (600 bytes average size) stored in

1MB SRAM.

2. Machine Grounding

The ACL is grounded through the input power cord. Consult local and
national electrical codes for proper grounding methods.

3. Machine Location

The ACL should be placed in a location where it can be protected from
damage. Lead lengths and accessibility must also be considered when
installing the ACL. The rear of the ACL must be a minimum of three inches
so that clean cooling air can circulate through the machine. Dirt, dust, or
any foreign material that can be drawn into the welder should be kept at a
minimum.

Keep the ACL in a dry, sheltered area, since a wet environment is a possible
safety hazard and may cause improper operation.

4. Input Power Connections

The Input Power Cord has a standard 120 VAC power plug on one end and a
16-pin Amphenol connector on the other end.
The Input Power Cord is wired for the voltage and phase which was specified
when the ACL was ordered.

This manual is related to the following products: