To accomplish this on the HHC, press the [PRINT MENU] button on the
HHC or the “P” on the keyboard for the PRINT MENU on the HHC screen
followed by option [0 Erase Log on Disk].

When selected, the library of logs that are on the diskette will appear; this
will appear similar to the procedure library.

Use the cursor keys to select the log to be erased.

Pressing [ENTER] will ask you to accept erasing of the selected log.

Press “Y” or [YES] to erase. Press “N” on the keyboard, or [NO] on the
HHC to keep.

6.5 “Save Log” allows the operator to save the current weld log to a floppy

diskette or USB or Ethernet storage.

From the MAIN SCREEN, select Log/Save As...

To accomplish this on the HHC, press the [PRINT MENU] button on the
HHC or the “P” on the keyboard for the PRINT MENU on the HHC screen
followed by option [T Copy Log to Disk].

The saved weld log can now be utilized on any PC that has Microsoft
Excel

©

loaded. In this program, the results from the weld log (deviations,

amps, volts and motor speed) can be examined and plotted to resemble
the Strip Chart printout.

This is especially useful when either of the save options are not
enabled, but the operator needs to save a particular log.

When doing so, the Short Log File function still applies. Meaning
if Short Log File is enabled, then when the log is saved, only
the procedure parameter information will copy and not the weld
performance data.