beautypg.com

MK Products Advanced Color Logic User Manual

Page 49

background image

Advanced Color Logic Owner’s Manual - Page 42

Modifying Procedures

If you decide to make changes to an existing procedure, clicking on the Weld Procedure icon will

open up the window that allows for modifications.
Known as MK Edit, this window consists of three tabs, each allowing for the welder to input

additional information. The first tab, Weld Record, allows modification of weld level parameters. After

selecting a level (with the mouse or arrow keys), you can then click and drag the mouse within the tube to
mark the level length and it will change the Ends At value for the selected level (Figure 7).

Clicking on any other parameter in the table also allows it to be changed (Figure 8).
You can also make changes to the ID strings, located at the top right of the window. Below these fields you
can also adjust the max scale, pre and post purge seconds, strike current and number of tacks. For more

information on the significance of these changes, please consult your owner’s manual.

Figure 8

Figure 7

Click and drag mouse

to adjust level length

Changes from mouse

are also reflected here

Click in any field

to make changes