Teach-in-methoden, Analog output setting, Switch output setting – Microsonic LCA-2 User Manual
Page 40

Page 40 of 51
Parameter change in the web edge sensor bks+
T
EACH
-
IN
-M
ETHODEN
To adjust the zero position of the edge to be controlled, the sensor can be calibrated with two options.
Completely freeing the fork from the web material
push
, then completely fill sensor fork and
push
.
Or align the web edge inside the fork with the two marks to ensure a 50 % coverage of the sound path,
then push
.
Ready.
A
NALOG OUTPUT SETTING
The analog output can be adjusted so that it supplies current or voltage. The characteristic can be
selected as rising or falling.
Voltage / Current Increasing:
voltage / current increases with higher coverage
Voltage / Current falling:
voltage / current drops with higher coverage
S
W ITCH
O
UTPUT
S
ETTING
The switched output of the bks+../FIU or bks+../F can be used e.g. for monitoring purposes. He switches
around the (adjustable) center in a (adjustable) window.