Microsonic sks-15/D User Manual
Microsonic Sensors
Sensor adjustment with Teach-in procedure
Set detect point
Place object at position ➀
Press push-button for about
3 s until LEDs flash
simultaneously
both LEDs:
flash
mutually
Press push-button for
about 1 s
Set window mode
Place object at position ➀
Press push-button for about
3 s until LEDs flash
simultaneously
both LEDs:
Place object at position ➁
Press push-button for
about 1 s
flash
mutually
Set two way reflective
barrier
Set NOC/NCC
Enable/disable Teach-in
push-button
Switch off power supply
Place reflector at position ➀
Press push-button for about
3 s until LEDs flash
simultaneously
Press button for about 13 s
until LEDs flash
mutually
both LEDs:
flash
mutually
Press push-button for
about 10 s
green LED:
yellow LED:
To change output characte-
ristic press push-button
for about 1 s
While pressing the push-
button switch on power
supply
Keep push-button pressed
for about 3 s until both
LEDs flash simultaneously
flashes
on: NOC
off: NCC
green LED:
yellow LED:
flashes
on: push-button
enabled
off: push-button
disabled
To enable/disable Teach-in
press push-button
for about 1 s
Reset to factory setting
Switch off power supply
While pressing the push-
button switch on power
supply
Keep push-button pressed
for about 13 s until both
LEDs stop flashing
Normal operating mode
Wait for 10 s
Wait for 10 s
Normal operating mode
1
1
2
1
85 %
Operating Instructions
sks-15/D
sks-15/E
sks-15/CD
sks-15/CE
Ultrasonic proximity switch with
one switched output
Ultrasonic Sensors
Product Description
The sks sensor offers a non-contact
measurement of the distance to an
object which must be positioned
within the sensor’s detection zone.
The switched output is set in depen-
dence of the adjusted detect dis-
tance.
Via the push-button, the detect dis-
tance and operating mode can be
adjusted (teach-in). Two LEDs indi-
cate operation and the state of the
switched output.
The output function is changeable
from NOC to NCC.
Safety Notes
■
Read the operating instructions
prior to start-up.
■
Connection, installation and
adjustment works may only be
carried out by expert personnel.
■
No safety component in
accordance with the EU Machine
Directive
Proper use
sks ultrasonic sensors are used for
non-contact detection of objects.
Installation
■
Mount the sensor at the installa-
tion site.
Maximum torque: 0,5 Nm
■
Connect a connection cable to the
M8 device plug.
Fig. 2: Pin assignment with view onto sensor
plug and colour coding of the
microsonic connection cable
3-pin initiator plug
1
+U
B
colour
brown
3
4
4-pin initiator plug
-U
B
D
blue
black
colour
1
3
4
2
+U
B
-U
B
brown
blue
D
Com
black
white
1
4
3
1
4
3
2
Start-Up
■
Connect the power supply.
■
Carry out the adjustment in
accordance with the diagram.
Factory Setting
■
Operation with one detect point
■
Switched output on NOC
■
Detect points at operating range
Operating modes
Three operating modes are available
for the switched output:
■
Operation with one detect point
The switched output is set if the ob-
ject falls below the set detect point.
■
Window mode
The switched output is set if the ob-
ject is within the set window mar-
gins.
■
Two-way reflective barrier
The switched output is set if the ob-
ject is between sensor and reflector.
Checking operation mode
■
In normal mode shortly press the
push-button.
The green LED stops shining for one
second, then it will show the current
operation mode:
1 x flashing = operation with one
switching point
2 x flashing = window mode
3 x flashing = reflective barrier
After a break of 3 s the green LED
shows the output function:
1 x flashing = NOC
2 x flashing = NCC
Maintenance
microsonic sensors are maintenance-
free. In case of excess caked-on dirt
we recommend cleaning the white
sensor surface
Notes
■
sks-15/CD and sks-15/CE sensors
have internal temperature com-
pensation. Because the sensors
heat up on their own, the tempe-
rature compensation reaches its
optimum working point after ap-
proximatly 30 minutes of operati-
on.
The sensors sks-15/D and sks-15/E
have no temperature compensati-
on.
■
The sks sensor has a blind zone,
within which distance measure-
ments are not possible.
■
In the normal operating mode, an il-
luminated yellow LED signals the
switched output is switched
through.
■
If the object to be sensed moves
into the detection area from the
side, the switching distance should
be set 8-10 % further than the de-
sired switch point to obtain a reli-
able object detection.
If the object moves towards the
sensor (e.g. level control) the de-
tect point can be taught to the ac-
tual distance at which the sensor
has to switch the output.
Set switched output
Further settings