Daqformaterror, Daqgetdevicecount, Daqgetdevicelist – Measurement Computing TempBook rev.3.0 User Manual
Page 150

11-26 daqCommand Reference (Enhanced API)
TempBook User’s Manual
daqFormatError
DLL Function
daqCalSelectInputSignal(DaqHandleT handle, DaqCalInputT input);
C
daqCalSelectInputSignal(DaqHandleT handle, DaqCalInputT input);
Visual BASIC
VBdaqCalSelectInputSignal(ByVal handle&, ByVal input as DaqCalInputT )
Delphi
daqCalSelectInputSignal( handle: DaqHandleT; input: DaqCalInputT)
Parameters
daqError
Daq* Enhanced API error code
msg
Pointer to a string to return the error text
Returns
DerrNoError
- No error (also, refer to API Error Codes on page 11-39)
See Also
daqSetDefaultErrorHandler, daqSetErrorHandler, daqProcessError, daqGetLastError,
daqDefaultErrorHandler
Program References
None
Used With
All devices
daqFormatError
returns the text-string equivalent for the specified error condition. The error
condition is specified by the daqError parameter. The error text will be returned in the character
string pointed to by the msg parameter. The character string space must have been previously
allocated by the application before calling this function. The allocated character string should be, at
minimum, 64 bytes in length. For more information on specific error codes refer to the API Error
Codes on page 11-39.
daqGetDeviceCount
DLL Function
daqGetDeviceCount(PDWORD deviceCount);
C
daqGetDeviceCount(PDWORD deviceCount);
Visual BASIC
VBdaqGetDevice&(deviceCount&)
Delphi
daqGetDeviceCount( var deviceCount:DWORD )
Parameters
deviceCount
Pointer to which the device count is to be returned
Returns
DerrNoError
- No error (also, refer to API Error Codes on page 11-39)
See Also
daqGetDeviceList, daqGetDeviceProperties
Program References
None
Used With
All devices
daqGetDeviceCount
returns the number of currently configured devices. This function will
return the number of devices currently configured in the system. The devices do not need to be
opened for this function to operate properly. If the number returned does not seem appropriate, the
device configuration list should be checked via the Daq* Configuration applet located in the Control
Panel. Refer to the configuration section in your device’s user manual for more details.
daqGetDeviceList
DLL Function
daqGetDeviceList(DaqDeviceListT *deviceList, PDWORD deviceCount);
C
daqGetDeviceList(DaqDeviceListT *deviceList, PDWORD deviceCount);
Visual BASIC
VBdaqGetDeviceList(deviceList as DaqDeviceListT, deviceCount&)
Delphi
daqGetDeviceList( var deviceList: DaqDeviceListT; var deviceCount: DWORD)
Parameters
deviceList
Pointer to memory location to which the device list is to be returned
deviceCount
Number of devices returned in the device list
Returns
DerrNoError
- No error (also, refer to API Error Codes on page 11-39)
See Also
daqGetDeviceCount, daqGetDeviceProperties, daqOpen,
Program References
None
Used With
All devices
daqGetDeviceList
returns a list of currently configured devices. This function will return the
device names in the deviceList parameter for the number of devices returned by the
deviceCount
parameter. Each deviceList entry contains a device name consisting of up to
64 characters. The device name can then be used with the daqOpen function to open the specific
device.
If the number returned does not seem appropriate, the device configuration list should be checked
via the Daq* Configuration applet located in the Control Panel. Refer to the configuration section in
your device’s user manual for more details.