Figure xiii. 640 channel-to-channel cross talk, Figure xiv. 650 channel-to-channel cross talk, Figure xiii. 640 channel-to-channel crosstalk – Measurement Computing IOtech 640 Series User Manual
Page 82: Figure xiv. 650 channel-to-channel crosstalk

Specifications are subject to change without notice.
11.b-8 Specifications, Plotted Data
967692
IOtech 640 and 650 Series
Figure XIII. 640 Channel-to-Channel Crosstalk
640 Channel to Channel Crosstalk
Vin = -0.5dB FS
-130
-120
-110
-100
-90
-80
-70
100
1,000
10,000
100,000
Frequency (Hz)
Crosst
al
k (d
BFS)
1-2
1-3
1-4
2-1
2-3
2-4
3-1
3-2
3-4
4-1
4-2
4-3
A Out to Ch 4
Specification -100dB typical
Measurement noise floor
Legend Format (aggressor - victim)
Figure XIV. 650 Channel-to-Channel Crosstalk
650 Channel to Channel Crosstalk
Vin = -0.5dB FS
-130
-120
-110
-100
-90
-80
-70
100
1,000
10,000
100,000
Frequency (Hz)
Cr
os
st
al
k (
dBF
S)
1-2
1-3
1-4
1-5
2-1
2-3
2-4
2-5
3-1
3-2
3-4
3-5
4-1
4-2
4-3
4-5
5-1
5-2
5-3
5-4
Specification -100dB typical
Measurement noise floor