Maxburstrate, Maxburstthruput, Maxscanrate – Measurement Computing DAQFlex User Guide User Manual
Page 77: Maxscanthruput

DAQFlex Software User's Guide
DAQFlex Message Reference – Reflection messages – AISCAN
77
MAXBURSTRATE
Get the maximum hardware-paced input scan rate for BURSTIO mode operations.
Message
"@AISCAN:MAXBURSTRATE"
Response
"AISCAN:MAXBURSTRATE=implementation>value"
implementation FIXED%, or not specified if value is NOT_SUPPORTED
value
The maximum scan rate for BURSTIO mode operations or returns
NOT_SUPPORTED if the device doesn't support analog input
BURSTIO operations.
Example
"AISCAN:MAXBURSTRATE=FIXED%200000"
MAXBURSTTHRUPUT
Get the maximum analog input throughput for BURSTIO mode operations.
Message
"@AISCAN:MAXBURSTTHRUPUT"
Response
"AISCAN:MAXBURSTTHRUPUT=implementation>value"
implementation FIXED%, or not specified if value is NOT_SUPPORTED
value
The maximum analog input throughput for BURSTIO operations, or
returns NOT_SUPPORTED if the device doesn't support analog input
BURSTIO operations.
Example
"AISCAN:MAXBURSTTHRUPUT=FIXED%2000"
MAXSCANRATE
Get the maximum hardware-paced input scan rate in samples per second.
Message
"@AISCAN:MAXSCANRATE"
Response
"AISCAN:MAXSCANRATE=implementation>value"
implementation FIXED%, or not specified if value is NOT_SUPPORTED
value
The maximum input scan rate, or returns NOT_SUPPORTED if the
device doesn't support analog input scan.
Example
"AISCAN:MAXSCANRATE=FIXED%1000"
MAXSCANTHRUPUT
Get the maximum analog input throughput in samples per second.
Message
"@AISCAN:MAXSCANTHRUPUT"
Response
"AISCAN:MAXSCANTHRUPUT=implementation>value"
implementation FIXED%, or not specified if value is NOT_SUPPORTED
value
The maximum throughput rate, or returns NOT_SUPPORTED if the
device doesn't support analog input scan
Example
"AISCAN:MAXSCANTHRUPUT=FIXED%200000"