Measurement Computing DAQFlex User Guide User Manual
Page 113

DAQFlex Software User's Guide
Hardware Reference – USB-1608G Series
113
Component
Supported
Property/Command
Set/Get
Supported Values
Get
Number of counter channels
START
STOP
VALUE
Get
0 to 4,294,967,295
Set
0
FLASHLED/{n}
Set
0 to 255
FWV
Get
MM.mm (M = major; m = minor)
ID
Set/Get
Up to 56 characters
MFGCAL
Get
yyyy-mm-dd HH:MM:SS
MFGCAL{item}
Get
YEAR as yyyy; 20xx
MONTH as mm; 01 to 12
DAY as dd; 01 to 31
HOUR as HH; 01 to 23
MINUTE as MM; 01 to 59
SECOND as SS; 01 to 59
MFGSER
Get
Up to 8 hexadecimal digits
RESET
Set
DEFAULT
TEMP
Get
Floating point numeric in ºC
Get
Number of digital ports
Get
8
DIR
Set/Get
IN, OUT
LATCH
Set/Get
0 to 255
VALUE
Set/Get
0 to 255
DIR
Set/Get
IN, OUT
LATCH
Set/Get
port number: 0
bit number: 0 to 7
port value: 0 to 255
bit value: 0, 1
VALUE
Set/Get
port number: 0
bit number: 0 to 7
port value: 0 to 255
bit value: 0, 1
Get
Number of timer channels
DELAY
Set/Get
0 to 67.11 s
DUTYCYCLE
Set/Get
0 to 100%
IDLESTATE
Set/Get
LOW, HIGH
PERIOD
Set/Get
31.25 ns to 67.11 s
PULSECOUNT
Set/Get
0 to 4,294,967,295 (a value of 0 indicates
continuous pulse generation)
START
STOP
1