Burstmode – Measurement Computing DAQFlex User Guide User Manual
Page 43

DAQFlex Software User's Guide
DAQFlex Message Reference – Programming messages – AISCAN
43
Get the size of the buffer used for AISCAN.
Message
"?AISCAN:BUFSIZE"
Response "AISCAN:BUFSIZE=value"
value
The size in bytes of the buffer.
BURSTMODE
Enable or disable the Burst mode scan option.
Message
"AISCAN:BURSTMODE=value"
Response "AISCAN:BURSTMODE"
value
ENABLE, DISABLE
Example
"AISCAN:BURSTMODE=ENABLE"
Note
If not set, BURSTMODE is set to DISABLE by default.
Get the state of the Burst mode operation.
Message
"?AISCAN:BURSTMODE"
Response "AISCAN:BURSTMODE=value"
value
ENABLE, DISABLE
CAL
Enable or disable calibration of the A/D data.
Message
"AISCAN:CAL=value"
Response "AISCAN:CAL"
value
ENABLE, DISABLE
Example
"AISCAN:CAL=ENABLE"
Note
This message is processed by the DAQFlex Software library, and is not sent to the
device.
Get a value indicating whether calibration coefficients will be applied to the raw A/D data.
Message
"?AISCAN:CAL"
Response "AISCAN:CAL=value"
value
ENABLE, DISABLE
Note
This message is processed by the DAQFlex Software library, and is not sent to the
device.