K-Patents SeedMaster 2 User Manual
Page 47

7 CONFIGURE SeedMaster 2
47
47
CONFIG. -> 3RD INPUT -> MOT. CONS.
1 /
SINGL E
M. CONS. (PH. 1 END)
KEYBOARD
KEYBOARD 3 . 3 kW
CR. CONT. (PH. 1 END)
KEYBOARD
KEYBOARD 2 5 %
MOT. CONS. (STRIKE END)
KEYBOARD
KEYBOARD 7 . 1 kW
LEVEL MEAS.
KEYBOARD
KEYBOARD YES
PAN MAX. LEVEL
KEYBOARD
KEYBOARD
7 7
%
CONC. (REFR., PH.1 END)
KEYBOARD
KEYBOARD
8 0 . 2%
PREV.
ACCEPT
BACK
1 / 2 SPEED
ACCEPT
CHANGE
BACK
ACCEPT
Fig. 7.9: The first page of configuration
NOTE:
1. All parameters can be entered by manual entry (KEYBOARD), or via digital data communication.
2. CR. CONT. (PH. 1 END) and FEED SYRUP PURITY have to be entered in Set-up -> Inputs.
Depending on the answer given to the first question (1 / 2 SPEED) naming of some parameters may be
different.
MOTOR: SINGLE SPEED
Parameters:
Range:
Notes:
1 / 2 SPEED
SINGLE (single speed motor, see Fig. 7.7)
MOT. CONS. (PH. 1 END)
0 < VALUE
Motor consumption at PHASE 1 END
must be larger than zero (A, or kW).
CR. CONT. (PH. 1 END)
10 – 45 %
This is the laboratory crystal content at
PHASE 1 END. Typical value: 25 % by
volume (point 2 in Fig. 7.7).
MOT. CONS. (STRIKE END)
0 < VALUE
Motor consumption at the end of the
strike, must be larger than zero (A, or kW).
LEVEL MEAS.
YES /NO
Level measurement is optional. If the answer
was NO, then instead of LEVEL data CR.
SIZE (mean size) will be displayed on the
MAIN DISPLAY.
PAN MAX. LEVEL
40 – 100 %
Only if YES was selected above.
CONC. (REFR., PH. 1 END)
65 – 95 %
Concentration measured by the refracto-
meter at PHASE 1 END.
CONC. (REFR., STR. END)
65 – 95 %
Concentration measured by the refracto-
meter at the end of the strike.
TEMP. (REFR., PH. 1 END)
30 - 85
˚C
Temperature measured by the refracto-
meter at PHASE 1 END : only if the motor
operates with SINGLE speed.
TEMP. (REFR., STRIKE END)
30 - 85
˚C
Temperature measured by the refractometer
at the end of strike or cooling crystallization.
CR. CONT. (STRIKE END)
0 - 60 %
Crystal content at the end of the strike
(% by volume). It must be specified in
Set up -> Inputs, and can not be entered
or modified here.
SEED CRYSTAL SIZE
0.005 – 1,5
If shock, or full seeding is practiced 0.01
mm is typical. The range covers the typical
values when crystal footing (magma) is used
for seeding.
PRODUCT CRYSTAL SIZE
0.03 - 6
Size in mm.
LENGTH OF CRYST. TIME
30 – 420 min
Length of the real time of crystallization
(from seeding to the end) in minutes. After the
1
st
strike the time of the last crystallization can
be accessed by going to DISPLAY -> TEST -
> OTHER DATA