Seedmaster 2 – K-Patents SeedMaster 2 User Manual
Page 40

7 CONFIGURE SeedMaster 2
40
40
2.) Basic (or "stand alone") application, handling 2 pans using a PR-23-... refractometer
with 2 sensor heads. Automatic seeding by SeedMaster 2.
Option: Monitoring SeedMaster 2 inputs / outputs on a PCS using MODBUS serial communication.
Start of strike (A)
SeedMaster 2
Seed warning (A)
Seeded (A)
DI1…8
DO1…4
Change syrup (A)
Seeding valve (A)
Pan 1
3rd input (A)
AI1…8
Sensor (A)
Ethernet
COM1…3
PCS
PR-23-…
Sensor (B)
Start of strike (B)
Pan 2
Option
Seeded (B)
Seed warning (B)
DI1…8
Change syrup (B)
DO1…4
AI1…8
Seeding valve (B)
3rd input (B)
SeedMaster 2 inputs:
concentration (A) & (B) Ethernet (K-PATENTS UDP / IP)
temperature (A) & (B)
3rd input: (A) & (B) AI1…AI8
Seedmaster 2outputs (option):
monitoring on a PCS, COM1…3
3.) SeedMaster 2 integrated in a PCS. Parameters and commands come from the PCS using MODBUS
communication. Automatic seeding by the PCS based on data from Seedmaster 2.
SeedMaster 2
Seed warning
COM
COM1…3
PR-01-S
COM1…3, OR Ethernet
PCS
AI1…8
3rd input
Seeding valve
SeedMaster 2 inputs:
concentration COM1…3
temperature
3rd input: AI1…8, or COM1…COM3 (MODBUS) or Ethernet (MODBUS)
Commands, parameters from the PCS: COM1…COM3 (MODBUS) or Ethernet (MODBUS)
SeedMaster 2 outputs: COM1…COM3 (MODBUS) or Ethernet (MODBUS)