Seedmaster 2 – K-Patents SeedMaster 2 User Manual
Page 39

7 CONFIGURE SeedMaster 2
39
39
Due to the large flexibility resulting from the use of the above resources, a large number of I / O combinations
can be realized. Fig. 7.3 shows the basic I / O traffic organization of SeedMaster 2.
SeedMaster 2 relies on the use of process refractometers manufactured by K-PATENTS OY, Finland. The
main data output features of the presently available K-PATENTS refractometers can be summarised as
follows:
Refractometer:
Analog output:
Communication
Communication
(4 – 20 mA)
(RS232, RS422, RS485)
(Ethernet)
PR-01-S
1
YES, 1 port
NO
(single sensor)
+ 1 (option)
PR-23- …
2
NO
YES
(2 sensors)
SeedMaster 2 is prepared to be used with any combination of K-PATENTS process refractometers and can
be readily integrated in a Process Control System (PCS) with compatible I / O data traffic (analog, digital I /
O, and / or digital data communication) features.
Application examples
1.) Basic (or "stand alone") application, handling a single pan using a PR-01-S refractometer.
Automatic seeding by Seedmaster 2.
Option: SeedMaster 2 analog current outputs connected to a monitoring PCS.
SeedMaster 2
Start of strike
Seed warning
Seeded
DI1…8
DO1…4
Seeding valve
Change syrup
COM1…3
PR-01-S
.
3rd input
AO1…4 .
PCS
AI1…8
.
Option
SeedMaster 2 inputs:
concentration COM1…3
temperature
3rd input AI1…8
SeedMaster 2 outputs (option):
up to 4
calculated
or measured
AO1…4
parameters