Nc c no – Hypertherm HD4070 Rev.1 User Manual
Page 88
![background image](https://www.manualsdir.com/files/789619/content/doc088.png)
1-TORCH INSTALLATION
HyPerformance HD4070
Instruction Manual
3A-15
X-Y lifter assembly optional torch breakaway kit mounting details
Fiberglass bracket
Breakaway
X-Y lifter
Hex screws (4)
Hex screws (2)
Connect to
emergency
stop circuit
Tubing
6 screws
Collar
Collar
Block
Brown
33.34 mm
(1-5/16 inch)
Filter / regulator
Breakaway
Breakaway
pressure switch,
normally open
Moisture drain
Inlet port
1/4 inch NPTF
6.9 bar (100 psi)
Customer supplied
hex screws (2)
4 mm x 40 mm
or 8-32 X 1-1/2 inch
Blue
(not connected)
Black
Tubing connector
Spacer and 4 hex screws not
used if breakaway is installed.
10
1
1
2
3
3
6
4
5
5
7
8
10
8
3
2
NC
C
NO
Pressure gauge
This manual is related to the following products: